| OUTSTANDING
FEATURES | | Coal
Tar enamel, when used in conjuction with coal tar & synthetic primer, ensures
quality field of corrosion for all kinds of pipelines and is the first choice
in the field of corrosin protection due to the following qualities:
- Excellent
ease of application
- Resistance
to cold flow
- Extremely
low water absorption
- Excellent
chemical stability
- High
electrical sensitivity
- Good
resistance to impact during backfill
- Resistance
to soil stress
- Flexibility
- Temperatures
susceptibility
- Resistance
to soil bacteria and marine organisms.
| |
| CHARACTERSTICTS
LOID T- 11 |
| Specifications |
AWWA-C-203-91 |
BS-4164-87 |
IS:10221-1982 |
| Grades |
Type-I |
Type-II |
105/15 |
105/8 |
120/5 |
Type-I |
Type-II |
| Softening
point°C | 104-116 |
104-116 |
105-116 |
105-116 |
120-130 |
104-115 |
104-115 |
| Filler
Content % | 25-35 |
25-35 |
25-35 |
25-35 |
25-35 |
25-35 |
25-35 |
| Specific
gravity | 1.4-1.6 |
1.4-1.6 |
1.4-1.6 |
1.4-1.6 |
1.4-1.6 |
1.4-1.6 |
1.4-1.6 |
Penetration
at 25°C-100gms/5sec at 48°C-50gms/5 sec |
5-10 12-30 |
10-20 15-55 |
10-20 15-55 |
5-12 8-30 |
1-9 3-16 |
5-10 12-30 |
10-20 15-55 |
Flow
time, Seconds 230°C 240°C |
- -
|
|
9.16 -
|
9.16 -
|
- 9.24
|
9.16 -
|
9.16 -
|
Sag Test (mm) 70/71°C
80/80°C |
1.6 -
|
1.6 -
|
1.5 -
|
1.5 -
|
- 1.5
|
1.6 -
| |
Low Temp test (-) 30.0°C
(-) 28.9°C (-) 25.0°C (-) 23.3°C (-) 20.0°C |
- NA - - None -
|
- None - NA -
|
None - - - -
|
- - None - -
|
- - - - None
|
- - - - -
|
- - - - -
|
Impact
test Disbonded area mm2 / 650gms / 2.45m/250 C Direct Indirect
|
10323 3871
|
6452 1290
|
- -
|
10000 -
|
- -
|
10300 3900
|
6450 1300
|
Peel
test(max) mm 27/30°C 38/40°C 49/50°C 60/60°C
70/71°C |
N/P N/P N/P N/P N/P
|
N/P N/P N/P N/P N/P
|
3.0 3.0 3.0 - -
|
- 3.0 3.0 3.0 -
|
- - - 3.0 3.0
|
N/P N/P N/P N/P N/P
|
N/P N/P N/P N/P N/P
|
| Cathodic
disbondment in 28 days (max) mm |
- |
- |
5.0 |
5.0 |
5.0 |
- |
- |
Bend test at 0°C first crack
(min.) mm Initial After heating |
- -
|
- -
|
20.0 15.0
|
15.0 10.0
|
- -
|
12.0 7.5
|
20.0 15.0
|
Disbonded
area (max.) mm2 Initial After heating |
- -
|
- -
|
2000 3000
|
3000 5000
|
- -
|
3200 5200
|
1950 3200
|
Service
temp °C Interior Lining Exterior Lining |
32.2 71.1
|
32.2 71.1 |
- -30 to +65
|
- -20 to +65
|
- -5 to +65
|
32.2 71.1
|
32.2 71.1
|
|
Application temp ° C |
230-240 |
230-240 |
250(max) |
250(max) |
260(max) |
230-240 |
230-240 | |